3680w Solar Inverter Single Phase SPH 3600TL BL-UP DC AC Growatt Hybrid Inverter
|
Datasheet |
SPH3000TL BL-UP |
SPH3600TL BL-UP |
SPH4000TL BL-UP |
SPH4600TL BL-UP |
SPH5000TL BL-UP |
SPH6000TL BL-UP |
| Input data(PV) | ||||||
| Max. recommended PV power (for module STC) | 6000W | 7200W | 8000W | 9200W | 10500W | 11200W |
|
Max. DC voltage |
550V | |||||
| Start voltage | 120V | |||||
| MPP voltage range | 120-550V/360V | |||||
| No. of MPP trackers | 2 | |||||
| No. of PV strings per MPP tracker | 1 | |||||
| Max. input current per MPP tracker | 13.5A | |||||
| Max short-circuit current per MPP tracker | 16.5A | |||||
|
Output data(AC) |
||||||
|
AC nominal power |
3000W |
3680W | 4000W | 4600W | 5000W | 6000W |
|
Max. AC apparent power |
3000VA | 3680VA | 4000VA | 4600VA | 5000VA | 6000VA |
|
Nominal AC voltage (range) |
230V/(180Vac-270Vac) | |||||
| AC grid frequency (range) | 50Hz/60Hz (45Hz-55Hz/55Hz-65Hz) | |||||
|
Max. output current |
16A | 16A | 22A | 22A | 27A | 27A |
| Adjustable power factor | 0.8leading...0.8lagging | |||||
| THDI | <3% | |||||
|
AC grid connection type |
Single phase | |||||
|
Battery data (DC) |
||||||
| Battery voltage range | 42-59V | |||||
|
Max charging and discharging current |
66A | 75A | 85A | 85A | 85A | 85A |
|
Continuous charging and discharging power |
3000W | 3680W | 4000W | 4000W | 4000W | 4000W |
| Type of battery |
Lithium /Lead-acid |
|||||
|
Backup power(AC) |
||||||
| Max. AC output power | 3000W | 3680W | 4000W | 4000W | 4000W | 4000W |
| Max. output current | 17.4A | |||||
|
Nominal AC output voltage |
230Vac | |||||
| Nominal AC output frequency | 50/60HZ | |||||
| THDv | <3% | |||||
|
Switch time |
<10ms | |||||
|
Efficiency |
||||||
| MAX. efficiency | 97.20% | 97.20% | 97.30% | 97.40% | 97.50% | 97.60% |
|
European efficiency |
97% | 97% | 97.10% | 97.10% | 97.20% | 97.20% |
|
MPPT efficiency |
>99.5% | |||||
|
Protection devices |
||||||
| DC switch |
Yes |
|||||
| DC reverse polarity protection | Yes | |||||
| AC/DC surge protection | Yes | |||||
| Battery reverse protection | Yes | |||||
| AC short-circuit protection | Yes | |||||
| Ground fault monitoring | Yes | |||||
| Grid monitoring | Yes | |||||
| Anti-islanding protection | Yes | |||||
| Residual-current monitoring unit | Yes | |||||
| Insulation resistance monitoring | Yes | |||||
|
General data |
||||||
|
Dimensions (W/H/D) |
458/565/188mm |
|||||
| Weight | 31kg | |||||
| Operating temperature range | -25°C ... +60°C | |||||
| Nighttime power consumption | < 10 W | |||||
| Topology | Transformerless | |||||
| Cooling | Natural | |||||
| Protection degree | IP65 | |||||
| Relative humidity | 0-100% | |||||
| Altitude | 2000m | |||||
| PV DC Connection | H4/MC4(Optional) | |||||
| Battery DC Connection | OT Terminal | |||||
|
AC connection |
Connector | |||||
|
Display |
LCD+LED | |||||
| Interfaces:RS485/CAN/USB | Yes | |||||
| Monitor: RF/WIFI/GPRS | Optional | |||||
|
Warranty: 5 years/10 years |
Yes/Optional | |||||
| Specification | ||||||
| SPH 3000-6000TL BL-UP | on&off grid single phase inverter | |||||
|
CE, IEC62109, G98/G99, VDE0126-1-1, AS4777, CEI 0-21, VDE-AR-N4105, UTE C 15-712, EN50549, IEC 61727, IEC 62116, IEC 62040, C10/11, NRS 097-2-1 |
||||||